Description
Suture Wire used to hold body tissues together after an injury or surgery. Application generally involves using a needle with an attached length of thread to stitch the wound shut.
Suture Wire comes in different diameters and lengths. Suture Wire diameters are measured in SWG (Standard wire gauge) or Millimeter. Ortho Care Suture Wires are made from SS 316L material.
Available Suture Wire sizes are
- 16 SWG (1.60mm)
- 18 SWG (1.25mm)
- 20 SWG (0.90mm)
- 22 SWG (0.70mm)
- 24 SWG (0.55mm)
- 26 SWG (0.45mm)
- 28 SWG (0.35mm)
- 30 SWG (0.30mm)
Suture Wire Uses
Suture Wire helps to achieve stable reduction of femoral fractures which can then be supplemented with a nail or a plate. The minimally invasive technique and instrumentation offer the advantage of minimal soft tissue dissection, and the procedure is associated with excellent outcomes without any major complications.
- stabilization and fixation of proximal femur in cases of periprosthetic fractures of the femur, subtrochanteric fractures or as a prophylactic banding in total joint hip arthroplasty.
- fractures of the patella
- acetabular fractures
- acromioclavicular joint dislocation
Suture Wire has been used in the past for osteosynthesis of femoral fractures. However, the technique went into disrepute as extensive soft tissue dissection, and periosteal stripping increased the risk of bone necrosis and delayed union. Advent of new instrumentation and minimally invasive technique has significantly reduced these complications. In spite of the limited indications for its application, reduction and stabilization with cerclage wiring can supplement osteosynthesis especially in spiral or oblique fracture morphology or those with a butterfly fragment instead of interfragmentary screw fixation.
Suture Wire techniques
There are many different Suture Wire techniques. Some of them are:
Continuous sutures
This technique involves a series of stitches that use a single strand of suture material. This type of suture can be placed rapidly and is also strong, since tension is distributed evenly throughout the continuous suture strand.
Interrupted sutures
This suture technique uses several strands of suture material to close the wound. After a stitch is made, the material is cut and tied off. This technique leads to a securely closed wound. If one of the stitches breaks, the remainder of the stitches will still hold the wound together.
Deep sutures
This type of suture is placed under the layers of tissue below (deep) to the skin. They may either be continuous or interrupted. This stitch is often used to close fascial layers.
Buried sutures
This type of suture is applied so that the suture knot is found inside (that is, under or within the area that is to be closed off). This type of suture is typically not removed and is useful when large sutures are used deeper in the body.
Purse-string sutures
This is a type of continuous suture that is placed around an area and tightened much like the drawstring on a bag. For example, this type of suture would be used in your intestines in order to secure an intestinal stapling device.
Subcutaneous sutures
These sutures are placed in your dermis, the layer of tissue that lies below the upper layer of your skin. Short stitches are placed in a line that is parallel to your wound. The stitches are then anchored at either end of the wound.
Suture Wire removal
When your Suture Wires are removed will depend on where they are on your body. Some general guidelines are as follows:
- scalp: 7 to 10 days
- face: 3 to 5 days
- chest or trunk: 10 to 14 days
- arms: 7 to 10 days
- legs: 10 to 14 days
- hands or feet: 10 to 14 days
- palms of hands or soles of feet: 14 to 21 days
To remove your Suture Wires, your doctor will first sterilize the area. They’ll pick up one end of your suture and cut it, trying to stay as close to your skin as possible. Then, they’ll gently pull out the suture strand.
The broken Suture Wire
The body is a hostile environment for Suture Wire. Although the problems of electrochemical corrosion, direct chemical attack on the suture, and inflammation produced in reaction to the suture have been largley eliminated by the use of austenitic stainless steel wires, failure of the wires may still occur due to mechano-chemical cracking – the combined effect of insignificant stresses, usually from cold working, and insignificant chemical potentials produced by body fluids. Although stainless steel Suture Wire remains a satisfactory material for sternotomy closure or for reattaching costal cartilages, the two spectacular complications of a broken wire point out the need for care in using wire sutures. Bending, twisting, kinking and knotting must be avoided as much as possible.
Suture Wire General Techniques
Suture Wire refers to encircling fragments and tensioning the wire to hold fragments in alignment. Full cerclage wires encircle the entire circumference of the bone while hemi-cerclage wires are placed through holes in the bone to stabilize adjacent fragments. While hemi-cerclage techniques are described in many textbooks, this is a technique best avoided in most fracture repairs. It provides poor stability between fragments and can cause significant damage to fragments and blood supply when placed.
Suture Wires can be tightened in 1 of 2 ways. The wire ends may be twisted equally around each other producing a so-called “twist wire.” Alternatively, a wire may have a loop at one end allowing the free end to be passed through the loop and tightened around the bone. In both twist and looped Suture Wires, specially designed wire tighteners are available. Although it is possible to tighten Suture Wires without the benefit of these wire tighteners, the surgeon is strongly warned against this shortcut. Failure to purchase a wire tightener is false economy since these devices can apply much more tension than can be achieved by hand. The number one principle of successful Suture Wire application is that the wire must be tight. Which type of Suture Wire is preferred: twist or looped? To some degree this is based on personal preference and the differences do not have a major influence on surgical success. Research has shown that twist wires have better knot security but looped Suture Wires produce consistently more tension and fragment stability.
While Suture Wires can be valuable in fracture repair there is little doubt that they are the most often misused piece of orthopedic hardware and contribute to a high number of postoperative complications. A loose wire at a fracture site is virtual poison to the healing bone environment. As the loose wire moves back and forth it wipes out the vascular buds trying to revascularize and heal the fracture. The result is no blood supply, no healing, and a non-union. To successfully utilize Suture Wires the following rules must be strictly adhered to:
- The wire must be tight!
- The wire must be of sufficient diameter for the particular application. Err on the side of a wire that is too heavy rather than one that is too light.
- Suture Wires are never used as the sole means of fracture stabilization.
- Wires must be placed perpendicular to the long axis of the bone.
- Never use only 1 wire. Always use at least 2, preferably more.
- Care must be taken in proper spacing of wires. They must be placed at least a 1/2 cm from the fracture ends and spaced approximately 1 cm apart. If it is not possible to satisfy rules #5 and #6 at the same time, then the fracture is not amenable to wire fixation.
- If wires are used to stabilize a fracture then fragments must be anatomically reduced and the over-all fracture repair must be fashioned to eliminate the possibility of fracture collapse. For example, a comminuted fracture may not be suitable for wire fixation if there is a chance one fragment will shift and cause collapse of the other adjacent fragments. Such an occurrence will leave a mass of avascular bone fragments encircled by loose wires; a disaster waiting to happen!
Warnings and Precautionary for Suture Wire
Before using Suture Wire, the surgeon and ancillary staff should study the safety information in these instructions, as well as any product-specific information in the product description, surgical procedures and/or brochures.
Suture Wires are made from surgical grade 316L Stainless Steel and are designed, constructed and produced with utmost care. These quality Suture Wires assure best working results provided they are used in the proper manner. Therefore, the following instructions for use and safety recommendations must be observed.
Improper use of this instrument can lead to damage to the tissue, premature wear, destruction of the instruments and injury to the operator, patients or other persons.
It is vital for the operating surgeon to take an active role in the medical management of their patients. The surgeon should thoroughly understand all aspects of the surgical procedure and instruments including their limitations. Care in appropriate selection and proper use of surgical instruments is the responsibility of the surgeon and the surgical team. Adequate surgical training should be completed before use of Suture Wires.
Factors which could impair the success of the operation:
- Allergies to implanted materials.
- Localized bone tumours.
- Osteoporosis or osteomalacia.
- System disease and metabolic disturbances.
- Alcohol and drug abuse.
- Physical activities involving excessive shocks, whereby the implant is exposed to blows and/or excessive loading.
- Patients who are mentally unable to understand and comply with the doctor’s instructions.
- Poor general health.
Possible Adverse Effects
The following adverse effects are the most common resulting from implantation:
- Loosening of the implant, which may result from cyclic loading of the fixation site and/or tissue reaction of the implant.
- Early and late infection.
- Further bone fracture resulting from unusual stress or weakened bone substance.
- Temporary or chronic neural damage resulting from pressure or hematomata.
- Wound hematomas and delayed wound healing.
- Vascular disease including venal thrombosis, pulmonary embolism and cardiac arrest.
- Heterotopic ossification.
- Pain and discomfort due to presence of the implant.
- Mechanical failure of the implant, including bending, loosening or breakage.
- Migration of implant resulting in injury.
Preoperative Planning for Suture Wire
The operating planning is carried out following a thorough clinical evaluation of the patient, Also, x-rays must be taken to allow a clear indication of the bony anatomy and associated deformities. At the time of the operation, the corresponding implantation instruments in addition to a complete set of implants must be available.
The clinician should discuss with the patient the possible risks and complications associated with the use of Suture Wires. It is important to determine pre-operatively whether the patient is allergic to any of the implant materials. Also, the patient needs to be informed that the performance of the device cannot be guaranteed as complications can affect the life expectancy of the device.